Label Options
|
- Construction-ID -
Considers objects placed in the project and associates labels with the Device
ID.
- Grounding Grid -
Places labels for grounding grid objects.
- Parts Based -
Places labels based on part numbers. This option is intended to place labels in
the construction drawings before they are imported into the project.
|
Part
|
When you select the Parts Based label option, you
have the ability to filter the list of parts in the parts database by the
following fields:
- Category - Select a
category to filter the list of parts by the category field in the parts
database.
- Discipline - Select
a discipline to filter the list of parts by the Discipline field in the parts
database.
- Manufacturer -
Select a manufacturer to filter the list of parts by the manufacturer field in
the parts database.
- Description -
Select a description to filter the list of parts by the category field in the
parts database.
- Part Number -
Select the part number for which you want to place a label.
- Accessory Kit - If
the selected part number has an associated accessory kit, the kit's name will
be displayed here.
|
Device ID
|
When you select the Construction - ID label option,
you have the ability to specify how the part number quantities should be
calculated and displayed in the BOM report. You have the option of placing on
the construction drawing using the Output BOM feature as described below:
- Quantity For
Project - Adds up all occurrences of the part number used throughout the
project and lists this quantity in the BOM report.
- Installation - Adds
up all occurrences of the part number used in the selected installation and
lists this quantity in the BOM report.
- Location - Adds up
all occurrences of the part number used in the selected location and lists this
quantity in the BOM report.
- Description1 - Adds
up all part number descriptions and lists the descriptions in the BOM report.
- Device Tag - Adds up
all occurrences of the part number sharing the selected device tag and lists
this quantity in the BOM report.
|
Label Tag
|
Enter a label name and press the + button to add a
label to a device in the drawing. You must enter data points to place the
leader line and label. The BOM report will only show parts that have been
labeled. If you specified a tag in the Label_Prefix field of the parts database
record, that label will automatically fill in.
|
ACK Parts
|
If you select a device that has an accessory kit
associated with it, the software will list each part number in the accessory
kit here. You can enter a tag prefix for each part number in the kit should you
choose to place a label for these accessory part numbers. If you specified a
Tag_Prefix in the Label_Prefix field of the parts database record, that
Tag_Prefix will automatically fill in.
|
Place Label
|
If you select a part number listed in the ACK Parts
table, you can select the Place Label button to place a label for this part
number. You must enter data points to place the leader line and label.
|
Refresh Tags
|
When a label/tag text is entered and then the symbol
inserted, it becomes locked so that it can be placed multiple times, but the
text will always be the same. If the user wants to change the text they must
remove all labels. At this point, the dialog will still show the label as red
text indicating it's locked. The refresh will clear any labels that no longer
exist on the currently active drawing so that new text can be entered.
|
Output BOM
|
Creates a Bill Of Materials based on the labels
placed in the drawing. The BOM contains the label ID, quantity, part number and
description. The template for the report is defined in the BOMTemplateName
project setting.
Note: The Device ID